• Login
    View Item 
    •   Mak IR Home
    • College of Health Sciences (CHS)
    • School of Bio-Medical Sciences (Bio-Medical)
    • School of Bio-Medical Sciences (Bio-Medical) Collections
    • View Item
    •   Mak IR Home
    • College of Health Sciences (CHS)
    • School of Bio-Medical Sciences (Bio-Medical)
    • School of Bio-Medical Sciences (Bio-Medical) Collections
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Performance evaluation of computational programs to predict Human leucocyte antigen (HLA) genotypes on African whole exome sequence data

    Thumbnail
    View/Open
    Master's Degree (1.287Mb)
    Date
    2023
    Author
    Agaba, Gerald Muzorah
    Metadata
    Show full item record
    Abstract
    Introduction: Accurate Human Leucocyte Antigen (HLA) genotyping is critical in studies involving the immune system and transplantation medicine. HLA genes encode proteins that have a central role in immune responses that are associated with rejection during organ transportation. HLA genotyping techniques have evolved from simple serologic methods to molecular analysis and recently the use of computational programs to type HLA genotypes using next-generation sequencing (NGS) data. Methodology This was a cross-sectional study nested in the Collaborative African Genomics Network (CAfGEN), HLA genotypes were made using six computational tools on 204 samples (124 from Baylor Uganda and 80 from Baylor Botswana). Objective The general objective of our study was to evaluate the technical performance of six computational programs/tools to predict HLA genotypes on African whole exome sequence data. Results: Regardless of the type of tool, each had the ability to call the three HLA class genotypes (A, B and C) and alleles to the second field (4-digit resolution) HLA-HD and Polysolver made call up to the third field (six-digit resolution), and was able to call 98.2% and 79.74% respectively of the samples. HISAT-genotype and HLA-VBSeq on the other hand were able to call up to 4th field (eight digit-resolution), calling 90.6% and 52.82% respectively of alleles. The highest percentage agreement between the tools at the genotype level was observed in HLA-C genotype, with HISAT-genotype having the Utmost agreement, and the lowest in HLAminer (89.71% vs 80.15% respectively), HLA-A subclass had the overall poorest agreement between the tools with the highest value observed with Polysolver (81.91%) and lowest with HLAminer (55.25%) compared to the six other tools, HLA-B subtype calls had on average slightly lower percentage agreement compare to HLA-C, with the highest percentage agreement observed with both Polysolver and HLA-HD at 88.53% and lowest with HLA-VBSeq at 69.75%. In terms of run time, Optitype had the shortest execution time of 7.37 (±1.82) minutes, followed by HLAminer at 19.31 (±4.61) minutes, HISAT-genotype at 31.48 (±6.64) minutes. HLA-VBSeq 59.52 (±12.6), HLA-HD at 85.92 (±31.41) minutes. Polysolver had the overall longest execution time of 97.10 (±7.91). Conclusion: The evaluation of these six publicly available HLA typing tools can help researchers to decide on the most appropriate HLA typing method for their NGS data and promote further development of high-performance tools, in this study we recommend the combination of different tools to achieve better results.
    URI
    http://hdl.handle.net/10570/12236
    Collections
    • School of Bio-Medical Sciences (Bio-Medical) Collections

    DSpace 5.8 copyright © Makerere University 
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of Mak IRCommunities & CollectionsTitlesAuthorsBy AdvisorBy Issue DateSubjectsBy TypeThis CollectionTitlesAuthorsBy AdvisorBy Issue DateSubjectsBy Type

    My Account

    LoginRegister

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    DSpace 5.8 copyright © Makerere University 
    Contact Us | Send Feedback
    Theme by 
    Atmire NV